F — individual oval master link
D, P and L identify the section and internal space needed for the hook and connecting components.
CHAIN SLINGS & COMPONENTS
The F oval master link and the FM assembly with two intermediate links are two upper connection configurations for sling assemblies. Compare dimensions, mass and WLL by article: the rating of a single link must not be transferred automatically to an assembly.
Price, availability and lead time for the selected article are confirmed on request.
D, P and L identify the section and internal space needed for the hook and connecting components.
A primary oval link with two intermediate links. D1, P1 and L1 are listed separately for the intermediate links.
For example, F28 is rated at 14.5 t, while F28M20 is rated at 11.8 t. Select the exact article and an approved loading arrangement.
We check markings, connecting dimensions and supply documents. Dimensions and a catalogue standard reference alone do not establish suitability for a particular lift.
Select a series. On mobile, scroll inside the table; the first column stays fixed. All values are available in the page without JavaScript loading.
| Article | D (mm) | P (mm) | L (mm) | Approx. mass (kg) | WLL max (t) |
|---|---|---|---|---|---|
| F22 | 23 | 270 | 140 | 2.5 | 6.7 |
| F25 | 25 | 270 | 140 | 3.0 | 8.9 |
| F28 | 27 | 270 | 140 | 3.5 | 14.5 |
| F32 | 33 | 270 | 140 | 5.4 | 24.15 |
| F36 | 36 | 270 | 140 | 6.5 | 28.91 |
| F40 | 40 | 275 | 150 | 8.3 | 34.29 |
| F45 | 45 | 340 | 180 | 12.8 | 38.3 |
| F50 | 50 | 350 | 190 | 16.5 | 50.56 |
| F60 | 60 | 430 | 230 | 29.1 | 67 |
| F70 | 70 | 480 | 260 | 44.6 | 85 |
| Article | D (mm) | P (mm) | L (mm) | D1 (mm) | P1 (mm) | L1 (mm) | Approx. mass (kg) | WLL max (t) |
|---|---|---|---|---|---|---|---|---|
| F22M16 | 23 | 270 | 140 | 17 | 140 | 80 | 4.0 | 6.7 |
| F25M18 | 25 | 270 | 140 | 19 | 135 | 75 | 4.8 | 8.9 |
| F28M20 | 27 | 270 | 140 | 20 | 135 | 75 | 5.7 | 11.8 |
| F28M22 | 27 | 270 | 140 | 23 | 180 | 100 | 7.0 | 14.5 |
| F32M26 | 33 | 270 | 140 | 27 | 180 | 100 | 10.4 | 17.1 |
| F36M30 | 36 | 270 | 140 | 30 | 190 | 110 | 13.1 | 24.1 |
| F40M32 | 40 | 275 | 150 | 33 | 200 | 110 | 16.7 | 28.1 |
| F45M36 | 45 | 340 | 180 | 36 | 225 | 125 | 24 | 38.3 |
| F50F40 | 50 | 350 | 190 | 40 | 275 | 150 | 33.1 | 45 |
| F60F50 | 60 | 430 | 230 | 50 | 350 | 190 | 62.1 | 67 |
| F70M56 | 70 | 480 | 260 | 56 | 400 | 200 | 91.2 | 85 |
D/P/L refer to the main link; D1/P1/L1 refer to an intermediate link. Dimensions are in mm and mass is approximate. Article codes, including F50F40 and F60F50, follow the supplied catalogue. Each WLL applies to its own row, not to the entire family.
Provide the load or container mass, lifting arrangement, number of legs and angles. For OF, specify the required container rating separately.
Check hook fit, link clearances, connector sections and chain diameter. Matching WLL alone does not establish compatibility.
Specify the exact article, sling length, quantity, operating conditions and documentation requirements. The quotation confirms the assembly contents.
We prepare quotations for Almaty, Aktau, Atyrau, Astana and other destinations across Kazakhstan. Delivery cost and conditions are agreed for the specific order.
Lifting.kz supplies high-quality lifting equipment for industrial customers. We check working load, component fit and documentation. Our experience with major corporate clients informs the supply approval process.
Send the article, quantity and lifting parameters through WhatsApp or sales@lifting.kz. We will select a configuration and prepare a quotation; no fixed price is stated on this page.
No. Selection also requires the loading arrangement, connection dimensions, leg count, angles and operating conditions. OF tables give container ratings, which do not replace review of the complete assembly.
The source catalogue does not list that value or combination. It is not zero and does not permit using data from an adjacent row; ask for confirmation during selection.
Products are supplied with manufacturer certificates and load test certificates issued by our company. Requirements for a particular standard and configuration are agreed when ordering.
Images, diagrams and tables are taken from the supplied TestCom Group sheets. Enlarge a view or open the complete sheet to check the original labels.